Instrument Rent
Instrument Rent

Equipment rental for diagnostics and measurement

COMMISSIONING IMPIANTI srl offers its customers a professional equipment rental service for diagnostics and testing.

Here is the list of instruments:
Balometers, anemometers, air duct leak test instruments, blower door tests, ultrasonic flow meters, pressure gauges, smoke generators, heat stress using the WBGT index.
All our equipment for the verification and testing of ventilation systems are certified in accordance with UNI ISO 10012-2, SIT/DKD and NIST standards.

Contact us to find out more and to request a detailed quote: we will offer you the assistance you need!

CERTIFIED INSTRUMENTS

All our instruments are suitably certified according to UNI ISO 10012-2, SIT/DKD and NIST standards to provide you with the equipment you were looking for!

COMPREHENSIVE ASSISTANCE

We offer you a comprehensive service for the rental of different equipment, delivering you highly professional tools.

noleggio-di-strumentazione-per-diagnostica-e-misurazione
Balometer ADM-850L
  • Measurement of differential pressure;
  • Accurate temperature readings;
  • Fast and accurate traverses of duct speed;
  • Automatic zero and range selection;
  • Flow and velocities corrected for air density;
  • New air balance precision.

View the PDF

noleggio-di-anemometro-per-misurazione
Anemometer AMI 310
  • Measurement of humidity, temperature, CO2, CO, speed and air flow, pressure, tachymeter (depending on model and probe);
  • Interchangeable modules;
  • Expandable memory with micro-SD card;
  • 2 inputs for Pt100 temperature;
  • Up to 6 simultaneous measurements;
  • Large color display.

View the PDF

gestione-di-prove-di-tenuta-canali-di-aria
XPT air duct leak test

Download the manual to find out how our XPT Air Duct Leak Test Tool works.

View the PDF

conduzione-di-misure-fonometriche-e-vibrazionali
Stress WBGT
  • Logging: Data acquisition and storage within the instrument. Duration can be set
    and, with the auto-start function, the date and time of start and end of storage.
  • The unit of measurement of the displayed temperature magnitudes: C, F, K.
  • The display of statistical parameters maximum, minimum, average.
  • Data transfer via software.
  • The instrument can detect the following quantities simultaneously:
  • Temperature of globe thermometer Tg.
  • Humid bulb temperature with natural ventilation Tn.
  • Room temperature T.

View the PDF

affitto-di-blower-global-test
Blower door tester (door fan test) retrotec
  • Digital Detector;
  • Controlled power;
  • Calibrated fan;
  • Simple Use with automated software.

View the PDF

noleggio-di-anemometro-per-misurazione
Balancing valves VIR T 650
  • High precision pressure measurement with fully differential pressure sensor and processing
    24-bit data from the pressure sensor;
  • Ability to reset differential pressure measurement for accurate pressure measurement
    very small differentials. Zero measurement is performed on the hydraulic bypass of the pressure sockets;
  • Midor device uses advanced digital technologies to compensate for inaccuracies normally associated with pressure measurements, such as temperature dependence and nonlinearity of measurements.

View the PDF

VDL500SMM - SMOKE MACHINE - 500W
  • Wireless remote control: Equipped with a wireless remote control for remote use that allows you to control your smoke machine within 15 meters
  • Efficient and Large Production: The fog machine produces uniform and odourless fog very quickly, after 2-3 minutes of heating. Fog production is about 3400 m³/h at a distance of 2-3 m;
  • Non-toxic and High Capacity: CE, RoHS and ETL certifications for the production of safe and non-toxic smoke; equipped with a 300 ml tank for long-lasting smoke production.
  • Compact Aluminum Body: Built in aluminum for better heat dissipation, so as to ensure durability and a long life cycle.
  • Content: Smoke machine with power cable and wireless remote control;
  • Liquid: SMOKE5L-HD – Liquid for high density smoke machines.

View the PDF

affitto-di-blower-global-test
Smart balancing valves
  • Measuring range;
  • Differential pressure: 0-1000 kPa;
  • Static pressure: < 1000 kPa;
  • System temperature: -30…+ 120 ;
  • Accuracy of the measurement;
  • Differential pressure: < 0.1% of full scale (at calibration pressure, 100 kPa);
  • Flow: see differential pressure + valve accuracy;
  • Temperature: < 0,2 volume C;
  • Battery capacity: 6,600 mAh;
  • Operating time: 35 hours in continuous operation;
  • Loading time: 6 hours;
  • Temperature during operation and loading: 0…40 ºC:
  • Temperature during storage: -20 C… 60 C
  • Ambient humidity: max 90% relative humidity;
  • Sensor weight: 540 g – Complete case: 2.8 kg;
  • IP Class: Sensor: IP65.
misuratore-di-portata-ad-ultrasuoni-in-noleggio
Solair particle counter
  • SOLAIR 3350: 0,3-25,0μm, 0,3μm @ 100 LPM;
  • SOLAIR 5350: 0,5-25,0μm, 0,5μm @ 100 LPM;
  • Sample 1 cubic meter in 10 minutes at 100 LPM;
  • Simultaneous display of up to 8 particle sizes;
  • Complies with 21 CFR Part 11 Secure data transfer via USB flash drive;
  • Extreme life laser diode technology >20 years MTTF laser life;
  • Thermal printer;
  • Stainless steel construction;
  • Designed for compliance with ISO 21501-4: Precision and repeatability guaranteed from unit to unit;
  • Multiple communication interfaces – USB, RS-485;
  • Ethernet and USB flash drives;
  • 5.7 inch TFT color touch screen display;
  • Data storage memory from 3000 records;
  • Database of recipes editable from 50 registrations;
  • User definable prints;
  • Open architecture connectivity with OPC servers;
  • Cleanroom overrun/error wizard: FS-209E, ISO-14644-1 or EU GMP Annex 1.

View the PDF

misuratore-di-portata-ad-ultrasuoni-in-noleggio
MP7 - Pressure and flow measurement instrument of a fire hydrant/hose system
Instrument for the certification of the performance of a fire extinguishing system with UNI45/70 hydrants and UNI25 pipes, through:

  • Measurement of static pressure;
  • Flow determination by measuring dynamic/residual pressure;
  • Hydrostatic test of the hydrant pipes to be carried out in accordance with UNI 10779 standards.

View the PDF

misuratore-di-portata-ad-ultrasuoni-in-noleggio
LT600

Air leakage meter.

  • Pressure measurement:
  • Principle: piezoresistive semiconductor sensor
  • Measuring range: ±7000 Pa
  • Resolution: 0.1 Pa to ±900 Pa, then 1 Pa
  • Accuracy: ±0.5 Pa or ±2.5 % of reading, depending on
    of which is the greater value
  • Volumetric flow measurement (for 1013 hPa and 20 °C):
  • Principle: Hot-wire anemometer
  • Measuring range: 0.0000 to 55.00 l/s (230 V, 50 Hz)
    0.0000 to 40.00 l/s (110V, 60 Hz)
  • Resolution: 0.0000 to 55.00 l/s (230V, 50 Hz)
    0.0000 bis 40.00 l/s (110V, 60 Hz)
    0.0001 l/s to 0.3000 l/s,
    0.001 l/s to 3.000 l/s, 0.01 l/s > 3.00 l/s
  • Accuracy: ± 0.0009 l/s or ± 5 % of reading, whichever is greater
  • Adapter measuring range (5% accuracy):
  • Adapter 0.3: 0.01 to 0.3000 l/s
  • Adapter 3.0: 0.300 to 3.000 l/s
  • Without adapter: 3.01 to 55.00 l/s
  • Electrical characteristics
  • Power supply: 230 V, 50 Hz – 110 V, 60 Hz with reduced volumetric flow rate (40 l/s)
  • Power consumption: max. 9 A
  • Operating temperature: 5 °C to 40 °C
  • Storage temperature: – 20 °C to + 50 °C
  • Weight: about 9.5 kg (without accessories)

View the PDF

termocamera-a-noleggio
HIKMICRO B20

Handheld Thermal Camera

  • Thermal resolution: 256 × 192 (49,152 pixels)
  • NETD : < 40 mK (@ 25°C,F#=1.0)
  • Temperature measurement range : -20°C to 550°C (-4°F to 1022°F)
  • Accuracy: Max (± 2°C/3.6°F, ± 2%), for ambient temperature 15°C to 35°C (59°F to 95°F) and object temperature above 0°C (32°F)
  • Measurement presets: Center spot, Hot spot, Cold spot, User Preset Point 25 Hz image frequency
  •  3.2’’ LCD screen display
  • Up to 6 hours continuous running

View the PDF